If you look at the documentation/help for PrintOut, you see that it is a ''security level 3'' method. That means that your form needs to be 'full trust' to use it.
Set your form to be full trust (Tools | Form Options | Security). This will require you to sign your form, register your form, or create an MSI to install it. You should be able to ...
-
Don't load it that way.
1. Create a data connection to the XML file (sounds like you've already done that).
2. Use the GetDOM() method to load your XML DOM into a variable.
3. You might need to set namespaces--if so, do that.
4. Access your XML DOM the same as you would the main DOM from the XDocument object.
-
Sorry -- you will need to use code-behind. The reason is that rules cannot insert a new row into your repeating section--it can only update values of existing rows.
If all you want to do is change an existing value (which is not really a log), then you can use rules. If you want to add a new row with the new values, then you need code-behind.
-
If you right-click the text box and choose Properties, on the Data tab there's a Default Value field that you can put your text into. This value will always appear when the field is first inserted. The user can then change it to whatever they want.
If you don't want an actual value (that would be saved with the form) you can go to the Display ...
-
You said you are on SP1. I would highly recommend being on SP2. Not that that will make a difference on this particular issue--but it might. SP2 has a number of bug fixes over SP1 (no new additional features).
So--this happens even when you create a brand-new form from scratch. Let me have you try this: Instead of working on just InfoPath, try ...
-
Please do a search in these forums about image issues. There have been some known issues when Internet Explorer 7 has been involved. Perhaps this is your issue too? If not, we might need more information to assist you.
-
Not sure I fully understand your question. The ''nested'' part is throwing me off.
In IP2007, one of my feature requests made it into the product, which allows you to right-click a node in the data source task pane, and copy the full xpath for that node to the clipboard. This feature, unfortunately, does not exist for IP2003.
One thing I ...
-
Thank you. We've taken care of this particular problem. If you encounter this again, please let us know. We want to keep these forums a pleasant place for users to get the information they need.
Please keep in mind that if you have your profile set up to allow other forum users to contact you, then you are at risk to such tactics. Luckily this ...
-
When you set up (or modify) your SQL data connection, there is a button that allows you to modify the SQL statement.
If this does not provide what you need, you can always write code behind your search button that updates the data connection query string with the correct SQL statement, and then force the query to happen.
-
Great! Glad when its the simple things!