Can you attach a stripped version of your form, so that we can look what is going wrong
-
i am not able to get your problem, what do you want to do with return key, What do you expect to do when return key is hit
-
you might need to configure infopath form services and change the default connection time out settings. to do so
go to your central admin -> Application Management-> configure infopath form services
change the default connection time out settings, by default it is 10000ms, set it to something higher and see if that helps
-
well the repeating table contains three columns, only two are shown, The third column contains the row number, on the repeating table i have set conditional formatting to show only, the row, whose rowno = field4, and on the buttons i set the value of field4,
right click the repeating table -> conditional formatting. you will see the condtions ...
-
well the control is date picker, it only takes date not the time, so when it goes to your database it goes only as date and is converted to date time and time is shown as 00:00:00.
you can use conditional formatting to set the date control to readonly state. right click the control -> conditional formatting set the condition and check the ...
-
Look at this kb article- http://support.microsoft.com/kb/939269.
Hope it solves your issue!
-
I was looking to hide the section and only make it available while printing. Just did not wanted them wondering about the 'readonly' fields.
Thanks for the direction. :)
-
I've got a form template that one user out of maybe 6-7 is getting a System out of memory error. I'm not finding a lot of information on this error outside of that it could be caused by too many fields, too many views, and/or too many contact selectors. It seems a little odd that only 1 person is running into this, so does ...
-
Wuz up peps......I gotta problem that hopefully has a quick solution........tryin ta create a text box in Infopath that is only three lines long.......but would like to be able to hit the "return" key to skip to the next line whenever I want.....I've tried all the different variations on the properties page without ...
-
Thanks Ernesto. Working fine now. Forgot the little matter of the Document Type Name in the submit.